<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>entree &#8211; architektur usw</title>
	<atom:link href="https://www.architekturusw.de/tag/entree/feed" rel="self" type="application/rss+xml" />
	<link>https://www.architekturusw.de</link>
	<description>günther &#38; schabert</description>
	<lastBuildDate>Tue, 05 Sep 2023 15:55:30 +0000</lastBuildDate>
	<language>de</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://www.architekturusw.de/wp-content/uploads/2023/08/a_usw-150x150.gif</url>
	<title>entree &#8211; architektur usw</title>
	<link>https://www.architekturusw.de</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>093 windfang / lobby</title>
		<link>https://www.architekturusw.de/gebaude-building/093-windfang-lobby.html</link>
					<comments>https://www.architekturusw.de/gebaude-building/093-windfang-lobby.html#respond</comments>
		
		<dc:creator><![CDATA[guenther und schabert]]></dc:creator>
		<pubDate>Thu, 18 Jun 2009 13:27:24 +0000</pubDate>
				<category><![CDATA[werk / oeuvre]]></category>
		<category><![CDATA[gebäude / building]]></category>
		<category><![CDATA[architekturusw]]></category>
		<category><![CDATA[holzkonstruktion]]></category>
		<category><![CDATA[architektur]]></category>
		<category><![CDATA[energie]]></category>
		<category><![CDATA[bauen im bestand]]></category>
		<category><![CDATA[martina guenther]]></category>
		<category><![CDATA[holz]]></category>
		<category><![CDATA[anbau]]></category>
		<category><![CDATA[einfach bauen]]></category>
		<category><![CDATA[holzbau]]></category>
		<category><![CDATA[093]]></category>
		<category><![CDATA[windfang]]></category>
		<category><![CDATA[martina günther]]></category>
		<category><![CDATA[wind-lobby]]></category>
		<category><![CDATA[jan schabert]]></category>
		<category><![CDATA[entree]]></category>
		<category><![CDATA[günther & schabert]]></category>
		<category><![CDATA[energy]]></category>
		<guid isPermaLink="false">http://www.architekturusw.de/?p=915</guid>

					<description><![CDATA[gegenstand die ag beabsichtigen an ihr bestehendes wohngebäude einen ungedämmten windfang anzuhängen. die konstruktion des korpus soll in wasserfest verleimtem furnierschichtholz ausgeführt werden. die konstruktion ist gleichzeitig die bewitterte außenfassade. ein leichtes dach schützt vor direkter bewitterung<a class="moretag" href="https://www.architekturusw.de/gebaude-building/093-windfang-lobby.html">Read More...</a>]]></description>
										<content:encoded><![CDATA[<p><a href="http://www.architekturusw.de/wp-content/uploads/2009/06/093_entreeflug.jpg"><img fetchpriority="high" decoding="async" title="093_entreeflug" src="http://www.architekturusw.de/wp-content/uploads/2009/06/093_entreeflug.jpg" alt="" width="640" height="853" /></a></p>
<p><span style="color: #ff00ff;">gegenstand</span><br />
die ag beabsichtigen an ihr bestehendes wohngebäude einen ungedämmten windfang anzuhängen.<br />
die konstruktion des korpus soll in wasserfest verleimtem furnierschichtholz ausgeführt werden.<br />
die konstruktion ist gleichzeitig die bewitterte außenfassade.<br />
ein leichtes dach schützt vor direkter bewitterung des korpus.<br />
die glas-fassade besteht aus einem feststehenden und einem schiebeelement.<span id="more-915"></span></p>
<p><a href="http://www.architekturusw.de/wp-content/uploads/2009/06/093_lp.jpg"><img decoding="async" class="alignnone size-full wp-image-2632" title="093_lp" src="http://www.architekturusw.de/wp-content/uploads/2009/06/093_lp.jpg" alt="" width="640" height="434" srcset="https://www.architekturusw.de/wp-content/uploads/2009/06/093_lp.jpg 640w, https://www.architekturusw.de/wp-content/uploads/2009/06/093_lp-300x203.jpg 300w" sizes="(max-width: 640px) 100vw, 640px" /></a></p>
<p><span style="color: #ff00ff;">ort</span><br />
das bv befindet sich in 81477 münchen, obersendling-thalkirchen</p>
<p><span style="color: #ff00ff;">bestand</span><br />
zweigeschossiger mauerwerksbau baujahr ca. 1935, verputzt sockel beton, verputzt<br />
im zuge der energetischen sanierung des kellers erhält der sockel eine außendämmung<br />
<span style="color: #ff00ff;">dimension</span><br />
außenmaße korpus, ca. 3,70 m x 1,40 m x 2,40 m [lxbxh]
<p><span style="color: #ff00ff;"> material</span><br />
kerto-Q 04/16, 90 mm, kesseldruckimprägmiert<br />
ausgewähltes furnier; beidseitig geschliffen</p>
<p><span style="color: #ff00ff;">development</span><br />
<a href="http://www.architekturusw.de/wp-content/uploads/2009/06/093_devlpmt_a.jpg"><img decoding="async" class="alignnone size-full wp-image-2162" title="093_devlpmt_a" src="http://www.architekturusw.de/wp-content/uploads/2009/06/093_devlpmt_a.jpg" alt="" width="640" height="701" srcset="https://www.architekturusw.de/wp-content/uploads/2009/06/093_devlpmt_a.jpg 640w, https://www.architekturusw.de/wp-content/uploads/2009/06/093_devlpmt_a-273x300.jpg 273w" sizes="(max-width: 640px) 100vw, 640px" /></a><br />
in the early stage of development, we intended to create a semi-monocoque construction in welded aluminium, integrating shelfing, lighting, the sliding-door track system etc.<br />
the construction does not have any foundation, it is to be constructed as a stiff box, invisibly suspended from its host.</p>
<p><a href="http://www.architekturusw.de/wp-content/uploads/2009/06/093_devlpmt_b.jpg"><img loading="lazy" decoding="async" class="alignnone size-full wp-image-2164" title="093_devlpmt_b" src="http://www.architekturusw.de/wp-content/uploads/2009/06/093_devlpmt_b.jpg" alt="" width="640" height="495" srcset="https://www.architekturusw.de/wp-content/uploads/2009/06/093_devlpmt_b.jpg 640w, https://www.architekturusw.de/wp-content/uploads/2009/06/093_devlpmt_b-300x232.jpg 300w" sizes="auto, (max-width: 640px) 100vw, 640px" /></a></p>
<p>due to approvement issues with aluminium as load-bearing material, and the budget-exceeding costs of this process, the design was continued in wood.</p>
<p><a href="http://www.architekturusw.de/wp-content/uploads/2009/06/093_devlpmt_c.jpg"><img loading="lazy" decoding="async" class="alignnone size-full wp-image-2163" title="093_devlpmt_c" src="http://www.architekturusw.de/wp-content/uploads/2009/06/093_devlpmt_c.jpg" alt="" width="640" height="567" srcset="https://www.architekturusw.de/wp-content/uploads/2009/06/093_devlpmt_c.jpg 640w, https://www.architekturusw.de/wp-content/uploads/2009/06/093_devlpmt_c-300x265.jpg 300w" sizes="auto, (max-width: 640px) 100vw, 640px" /></a></p>
<p>the set of stairs is standing independently in front of this completely foundationless structure.</p>
<p><a href="http://www.architekturusw.de/wp-content/uploads/2009/06/093_devlpmt_d.jpg"><img loading="lazy" decoding="async" class="alignnone size-full wp-image-2165" title="093_devlpmt_d" src="http://www.architekturusw.de/wp-content/uploads/2009/06/093_devlpmt_d.jpg" alt="" width="640" height="218" srcset="https://www.architekturusw.de/wp-content/uploads/2009/06/093_devlpmt_d.jpg 640w, https://www.architekturusw.de/wp-content/uploads/2009/06/093_devlpmt_d-300x102.jpg 300w" sizes="auto, (max-width: 640px) 100vw, 640px" /></a></p>
<p>it was delivered prefabricated in one piece &amp; in one hour, only requiering for a little preparation upfront and the attachment of the sliding elements consecutively.</p>
<p><a href="http://www.architekturusw.de/wp-content/uploads/2009/06/093_entreeankunft.jpg"><img loading="lazy" decoding="async" class="alignnone size-full wp-image-2166" title="093_entreeankunft" src="http://www.architekturusw.de/wp-content/uploads/2009/06/093_entreeankunft.jpg" alt="" width="640" height="480" srcset="https://www.architekturusw.de/wp-content/uploads/2009/06/093_entreeankunft.jpg 640w, https://www.architekturusw.de/wp-content/uploads/2009/06/093_entreeankunft-300x225.jpg 300w" sizes="auto, (max-width: 640px) 100vw, 640px" /></a></p>
<p>even though the material would have allowed for a completely unprotected fully horizontal roof, we added in agreement with the client a light and replaceable pitched roof.</p>
<p><a href="http://www.architekturusw.de/wp-content/uploads/2009/06/093_cut.jpg"><img loading="lazy" decoding="async" class="alignnone size-full wp-image-2633" title="093_cut" src="http://www.architekturusw.de/wp-content/uploads/2009/06/093_cut.jpg" alt="" width="640" height="640" srcset="https://www.architekturusw.de/wp-content/uploads/2009/06/093_cut.jpg 640w, https://www.architekturusw.de/wp-content/uploads/2009/06/093_cut-150x150.jpg 150w, https://www.architekturusw.de/wp-content/uploads/2009/06/093_cut-300x300.jpg 300w" sizes="auto, (max-width: 640px) 100vw, 640px" /></a></p>
<p><span style="color: #ff00ff;">Korpus</span><br />
Kerto Q 04/16 d=100mm; kesseldruckimprägniert, ausgewähltes Furnier, beidseitig geschliffen<br />
<span style="color: #ff00ff;">Verbindung Holz-Holz</span><br />
Appeldübel (Einlassdübel) d=65 mm; 4 Simplexverbinder M12, l=ca. 200 mm<br />
<span style="color: #ff00ff;">Verbindung Holz-Mauerwerk</span><br />
oben: lineare Aufhängung: L-Winkel, 120/80/10 mm, 16x Hilti hit HY 70, Klebeverfahren, Gewindestange M12 Edelstahl<br />
unten: 4x Stahlwinkel, Sonderanfertigung, verzinkt<br />
<span style="color: #ff00ff;">Glaselemente</span><br />
ESG 10 mm rahmenlos</p>
<p>tragwerk: andreas wild, münchen<br />
holzbau: <a href="http://www.stenger-holzbau.de" target="_blank" rel="noopener">stenger holzbau</a>, kraiburg</p>
<p>&nbsp;</p>
<p><a href="http://www.architekturusw.de/wp-content/uploads/2009/06/093_anhang.jpg"><img loading="lazy" decoding="async" class="alignnone size-full wp-image-2634" title="093_anhang" src="http://www.architekturusw.de/wp-content/uploads/2009/06/093_anhang.jpg" alt="" width="640" height="966" srcset="https://www.architekturusw.de/wp-content/uploads/2009/06/093_anhang.jpg 640w, https://www.architekturusw.de/wp-content/uploads/2009/06/093_anhang-198x300.jpg 198w" sizes="auto, (max-width: 640px) 100vw, 640px" /></a></p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.architekturusw.de/gebaude-building/093-windfang-lobby.html/feed</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>
